Technical indicators#
Maximum measuring range: voltage maximum 24V, current maximum 5A
Use 0.4% ± 20ppm precision reference chip, reserve 0.1% reference position, 0.1% precision resistor, 12 bit ADC design. The nominal accuracy is 1% (typical value is 0.5), and the user can further calibrate the accuracy to reach 0.1%。
Automatic measurement range: the current echo gears are 500 μA, 50mA and 5A respectively, which are automatically switched according to the current output current.
Gear switching speed: CC table adopts multi-channel synchronous sampling, no shift delay.
Voltage drop switching speed: CC meter uses 2/3 channel sampling resistor, and the maximum delay when the sampling resistor is short-circuited is 100uS
Current measurement accuracy: resolution 0.15 μA in 500μA gear and 100 μA in 50mA gear (table below)
Fixed multi-channel 10KHz sampling rate, USB high-speed data transfer
Can cooperate with PC client to view and analyze current waveform, can also use command line version to capture serial port data (such as strawberry pie) on any device (win/linux/mac), use pc client to import and view
Type |
Range |
Resolution |
Nominal Accuracy |
Actual Accuracy |
---|---|---|---|---|
Voltage Setting |
0V-21V |
20mV |
2% |
PD Tricking PPS Decision |
Voltage Readback |
0V-24V |
10mV |
1% |
<0.5% |
Current Setting |
0-3A |
50mA |
2% |
PD Tricking PPS Decision |
Current Range |
Range |
Resolution |
Nominal Accuracy |
Actual Accuracy |
Type |
---|---|---|---|---|---|
500μA |
0.1uA-500μA |
0.15μA |
1% |
<0.5% |
Automatic gear |
50mA |
500μA-50mA |
15μA |
1% |
<0.5% |
Automatic gear |
5A |
50mA-5A |
1.5mA |
1% |
<1% |